9 default communication parameters, Default communication parameters, Section – Kramer Electronics VS-88DTP User Manual

Page 38: 9default communication parameters

Advertising
background image

34

VS-88DTP - Default Communication Parameters

9

Default Communication Parameters

EDID

EDID data is passed between Output 1 and Input 1

RS-232

Protocol 2000

Protocol 3000 (Default)

Baud Rate:

9600

Baud Rate:

115,200

Data Bits:

8

Data Bits:

8

Stop Bits:

1

Stop Bits:

1

Parity:

None

Parity:

None

Command Format:

HEX

Command Format:

ASCII

Example (Output 1 to

Input 1):

0x01, 0x81, 0x81,

0x81

Example (Output 1 to

Input 1):

#AV 1>1<CR>

Switching Protocol

P2000 -> P3000

P3000 -> P2000

Command:

0x38, 0x80, 0x83,

0x81

Command:

#P2000<CR>

Ethernet

Default Settings

Reset Settings

IP Address: 192.168.1.39

Power cycle the unit while holding in the

Factory Reset button, located on the rear

panel of the unit.

TCP Port #: 5000
UDP Port #: 50000

The Windows®-based Kramer control software (available for
download the latest software from our Web site at

http://www.kramerelectronics.com)

operates with protocol 2000.

If the

VS-88DTP is set to protocol 3000, it is automatically switched

to protocol 2000

i