Kramer Electronics PL-18 User Manual

Page 11

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

PL-18 Commands in Protocol 3000

8

Explicit Binary Port Configuration Command

Config Serial port
(RS-232/1)

UART-CFG

PORT_NUM, BAUD,

DATA_BITS, PARITY, STOP_BITS[,

FLOW_CONTROL]

UART-CFG PORT_NUM, BAUD,

DATA_BITS, PARITY, STOP_BITS

[, FLOW_CONTROL] RESULT

Config IR out port

IR-CFG PORT_NUM,

CARRIER_FREQ, DUTY_CYCLE

IR-CFG PORT_NUM,

CARRIER_FREQ, DUTY, RESULT

Binary Data Send/Receive

Emit raw data via a
pre-configured binary
port

BIN PORT_TYPE, PORT_NUM,

RAW_DATA_SIZE START_TOKEN

RAW_DATA

END_TOKEN

1

BIN PORT_TYPE, PORT_NUM,

RAW_DATA_SIZE [ ] RESULT

Convey raw data
received through a
preconfigured binary
port

RBIN PORT_TYPE, PORT_NUM,

RAW_DATA_SIZE START_TOKEN

RAW_DATA

END_TOKEN

1

RBIN PORT_TYPE, PORT_NUM,

RAW_DATA_SIZE [ ] RESULT

2

Factory default values of binary ports:

IR1, IR2: Carrier frequency – 38000; duty cycle – 33
RS-232-1: 9600 baud, 8 data bits, parity NONE, 1 stop bit

Configuration and Operation Examples

A binary port must be configured properly before using it to send or receive binary data. The port may be used in

static or dynamic port scenarios:

Static binary port scenario – A specific binary port controls one specific external device (e.g. one RC
button opens a projector; another RC button closes it using the same serial binary port). The port is
configured only once at installation and the value is stored in the non-volatile memory of the PL-18.
Thereafter, when the RC button is pressed it only invokes the configured BIN commands on the PL-18.

Dynamic binary port scenario – A specific binary port controls various external devices (e.g. one RC
button opens a TV, another RC button opens a DVD, and both use the same IR binary port with a dual IR
emitter cable). The binary port must be reconfigured before issuing the BIN command to a different
device. At each RC button press, a CBIN command is sent to the PL-18 before sending a BIN command.

Configure UART (RS-232) port 1, with “9600,8,n,1” serial port configuration parameters:

Binary port configuration examples:

#cbin uart, 1, 9600, 8, n, 1 <CR>
or
#uart-cfg 1, 9600, 8, n, 1 <CR>


Configure IR port 2, with “38000,33” as infrared configuration parameters:
#cbin ir, 2, 38000, 33 <CR>
or
#ir-cfg 2, 38000, 33 <CR>





1 As opposed to any other P3000 command, CR cannot be added after the END_TOKEN

2 The RC responds with this command

Advertising