Connecting the FC-4046 Video MultiCoder®

9

6.2 Dipswitch Settings

Configure the

FC-4046 unit by setting the 8 dipswitches, as Figure 4 and

Table 4 define:

Figure 4: Dipswitches (Factory Default)

Table 4: Dipswitch Settings

Dipswitch

Set as follows:

1 PEDESTAL

1

ON for pedestal; OFF for no pedestal (7.5 IRE offset selection for NTSC)

2 STANDARD 1
3 STANDARD 2
4 STANDARD 3


See Table 5 (for selecting the INPUT video standard)

5 AUTO

2

ON for multi-standard; OFF for user-selected (fixed) standard

6 H SYNC

ON for Horizontal sync on Hs/Cs BNC; OFF for composite sync output

7 BAR

ON for machine to operate as a 75% color bar generator

3

8 AGC

4

ON for automatic gain control; OFF for fixed gain

Table 5: Dipswitch Standard Definitions

Standard

DIP Standard 1

DIP Standard 2 DIP Standard 3 DIP Auto

2

Auto Detection

OFF

OFF

OFF

ON

PAL

OFF

OFF

OFF

OFF

NTSC

OFF

OFF

ON

OFF

SECAM

OFF

ON

OFF

OFF

PAL-M

OFF

ON

ON

OFF

PAL-Nc

ON

OFF

OFF

OFF

PAL-60

ON

OFF

ON

OFF

NTSC 4.43

ON

ON

OFF

OFF


1 NTSC offsets the black level within the active video signal by 7.5 IRE when selected
2 If the AUTO dipswitch is set to ON, dipswitches STANDARD 1, STANDARD 2 and STANDARD 3 must be set to OFF.
The machine will auto select between PAL, NTSC, and SECAM only
3 When operating as a bar generator, it is recommended to connect an external CV source (50Hz or 60Hz, according to the
required output standard) in order to stabilize the color sub-carrier frequency
4 For firmware versions up to 2.0, the AGC function cannot be disabled. The AGC dipswitch is only relevant for firmware
versions 2.0 and higher