Your fc-4046 video multicoder – Kramer Electronics FC-4046 User Manual

Page 6

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Your FC-4046 Video MultiCoder®

4

Table 1: Front Panel FC-4046 Video MultiCoder® Features

# Feature

Function

1 POWER Switch

Illuminated switch for turning the unit ON or OFF

2 STANDARD LEDs

Indicates

1

the input video standard

2

, lighting the appropriate LED

3 INPUT Button

Press to choose the input format

3

4 INPUT LEDs

Light the specific INPUT chosen via the INPUT button

5 OUTPUT Button

Press to select the output standard on CV and YC outputs

6 OUTPUT LEDs

Light the specific OUTPUT chosen via the OUTPUT button

7 COMPONENT OUT

Button

Press to select the output

4

format on the component BNC connectors

8 COMPONENT OUT LEDs Light the specific COMPONENT OUT chosen via the COMPONENT OUT

button

9 Lower CONTROL LED

Selects the function printed under the lit ProAmp button

10 Upper CONTROL LED

Selects the function printed above the lit ProAmp button

Y CONTROL Button

11

BRIGHT Button
U CONTROL Button

12

CONTRAST Button
V CONTROL Button

13

SATURATION Button
SHARP CONTROL Button

14

HUE Button




Press the appropriate button once or twice (until the upper/lower LED is lit)

to select control of the Y / BRIGHTNESS / U / CONTRAST / V /

SATURATION / SHARP / HUE

5

. Adjust using the + and – buttons

15 + Button

Press to increase the level

6

16 - Button

Press to decrease the level

6

17 7-segment Display

Displays data when selecting a CONTROL button. After powering up the

machine, the firmware version number displays briefly for versions higher

than 1.0

18 PANEL LOCK LED

Lights when the panel is locked (blinks after pressing a button while the

panel is locked)

19 PANEL LOCK Button

Disengages the front panel buttons

1 When the FC-4046 is set to the Automatic mode
2 PAL (B/D/G/H/I/N), NTSC(3.58), SECAM, PAL (M/Nc/60) and NTSC (4.48)
3 CV, YC, YUV, RGsB, or RGBS
4 YUV, RGsB, or RGBS
5 Note that this function is not applicable to all standards
6 Operational only when the 7-segment display displays data after choosing a control button

Advertising