Kramer Electronics TP-126-od User Manual

Page 17

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

The TP-121-od / TP-122-od Transmitter / Receiver Set

14

5.3 Connecting the TP-121-od / TP-122-od Transmitter / Receiver

You can use the TP-121-od together with the TP-122-od to configure an
XGA/Audio Line-to-Twisted Pair Transmitter and Receiver system.

Before connecting the transmitter and receiver system you can acquire the

EDID (via TP-121-od) from the display or set the system to the default EDID,

see section

9

To connect the TP-121-od XGA / Audio Line Transmitter with the TP-122-od
XGA / Audio Line Receiver, as the example in

Figure 6

illustrates, do the

following:

1. On

the

TP-121-od, connect the XGA source (for example, a laptop’s

graphics card) to the XGA INPUT 15-pin HD (F) connector and an audio
source to the AUDIO IN 3.5mm mini jack, for example, using a Kramer
C-GMA/GMA cable (VGA 15-pin HD (M) +Audio jack to VGA 15-pin HD
(M) +Audio jack)

1

. Alternatively, you can connect an XGA source to the

XGA INPUT 15-pin HD (F) connector, and a separate audio source to the
AUDIO IN 3.5mm mini jack.

2. On

the

TP-122-od, connect the XGA OUT 15-pin HD (F) connector to

the XGA acceptor (for example, a display), and connect the AUDIO OUT
S/PDIF RCA connector to the digital audio acceptor (for example, an AV
Receiver), and the ANALOG 3.5mm mini jack to the analog audio
acceptor (for example, a stereo audio recorder).

3. Connect the LINE OUTPUT RJ-45 connector on the TP-121-od to the

LINE IN RJ-45 connector on the TP-122-od, via CAT 5 cabling (with a
range of more than 300ft (>100m)), see section

8

.

4. Connect the 12V DC power adapter to the power socket and connect the

adapter to the mains electricity on both

2

the TP-121-od and the TP-122-od.

The signal from the XGA source is transmitted via CAT 5 cable, decoded and
converted at the XGA OUT 15-pin HD (F) connector to the XGA acceptor.

5. If required, on the TP-122-od adjust

3

the video output signal level and/or

cable compensation equalization level.

1 Not supplied. The complete list of Kramer cables is on our Web site at

http://www.kramerelectronics.com

2 If you cannot connect the power to both the TP-121-od and TP-122-od, you can just connect the power to the TP-122-od

3 Use a screwdriver to carefully rotate the trimmer, adjusting the appropriate level

Advertising
This manual is related to the following products: