7

Figure 6

Figure 7

MORTAR

SLeeVe

FLex LINeR

FLex PULLeR

ROPe (NOT

INCLUDeD)

Figure 8

MORTAR

SLeeVe

B-VeNT

FeMALe

ADAPTOR

2 - 3 INCHeS

made in the chimney wall, break out

sufficient masonry to form an opening

large enough for the Mortar Sleeve

or Flex Liner to pass through easily.

If a Tee application is necessary, a

larger hole may be required (See Tee

Installation Section).

Step 3. extending the Flex Liner from

its compressed length requires two

people. extend half of the length at a

time by:

a. At the midpoint of the liner, face

each other. See Figure 5

b. Both holding firmly onto the

liner, one person steps backwards

FLEXIBLE LINER INSTALLATION

The basic flexible liner installation

procedure for gas appliances such as

Category I furnaces, water heaters,

and boilers is as follows:

Step 1. Measure and record the

interior dimensions of the masonry

chimney and the height of the chimney

from the top, down to the penetration

through the masonry where the liner

will pass.

Step 2. After locating where the

appliance flue connection will be

Advertising