Gb 3. specifications – WIKA AC-1 User Manual
Page 10

10
WIKA operating instructions pressure transmitter model AC-1
14026285.01 11/2012 GB/D/F/E
GB
3. Specifications
Vacuum and +/- measuring range
bar Measuring range
-1 ... +7
-1 ... +9
-1 ... +10
-1 ... +15
Overpressure limit
20
20
20
40
Burst pressure
25
25
25
50
Measuring range
-1 ... +20
-1 ... +25
-1 ... +29
-1 ... +45
Overpressure limit
40
40
100
100
Burst pressure
50
50
120
120
Measuring range
-0.5 ... +7
-0.5 ... +10
Overpressure limit
20
20
Burst pressure
25
25
psi Measuring range
-30 inHg ... +100
-30 inHg ... +145
-30 inHg ... +200
-30 inHg ... +250
Overpressure limit
300
300
600
600
Burst pressure
375
375
750
750
Measuring range
-30 inHg ... +300
-30 inHg ... +350
-30 inHg ... +400
-30 inHg ... +450
Overpressure limit
600
600
600
1,450
Burst pressure
750
750
750
1,800
Measuring range
-30 inHg ... +500
-30 inHg ... +550
-30 inHg ... +600
Overpressure limit
1,450
1,450
1,450
Burst pressure
1,800
1,800
1,800
Vacuum tightness
Yes