Gb 3. specifications – WIKA AC-1 User Manual
Page 11
Advertising

11
WIKA operating instructions pressure transmitter model AC-1
14026285.01 11/2012 GB/D/F/E
GB
3. Specifications
3.2 Output signals
Signal type
Signal
Current (2-wire)
4 ... 20 mA
Voltage (3-wire)
DC 0 ... 10 V
DC 1 ... 5 V
Ratiometric (3-wire)
DC 0.5 ... 4.5 V
Load in Ω
■
Current output (2-wire): ≤ (power supply - 7 V) / 0.02 A
■
Voltage output (3-wire): > max. signal / 1 mA
3.3 Voltage supply
The permissible power supply depends on the corresponding value of the output signal.
■
4 ... 20 mA:
DC 7 ... 30 V
■
DC 0 ... 10 V:
DC 14 ... 30 V
■
DC 1 ... 5 V:
DC 8 ... 30 V
■
DC 0.5 ... 4.5 V ratiometric: DC 4.5 ... 5.5 V
3.4 Reference conditions (per IEC 61298-1)
Temperature
15 ... 25 °C
Atmospheric pressure
860 ... 1,060 mbar