6. Commissioning, operation

Sealing of the process connection

For further information on sealings see WIKA data sheet AC 09.08 or under www.wika.com.

Rotatability of the case

The case of the model DG-10-E can be rotated through 300°, thus the

display can be read from almost any position.

Do not turn the case forcibly past the stop point.

Parallel threads

Tapered threads

Correct sealing of the process connections with

parallel threads at the sealing face

must be

made using suitable flat gaskets, sealing rings or

WIKA profile sealings.

For sealing process connections with tapered

threads, the sealing must be made in the threads

using additional sealing material, e.g. PTFE tape

(EN 837-2).

300°

per EN 837

per DIN 3852-E

NPT, R and PT