Specifications, Design and function, Specifications / 4. design and function – WIKA 851 User Manual

Page 8

Advertising
background image

GB

2435182.03 12/2010 GB/D/F/E

WIKA operating instructions electronic contact, model 830 E

8

3. Specifications

Specifications

Model 830 E

Range of operating voltage

DC 10 ... 30 V

Residual ripple

max. 10 %

No-lead current

≤ 10 mA

Switching current

≤ 100 mA

Leakage current

≤ 100 µA

Function of switching element

Normally open

Type of output

PNP transistor

Voltage drop (with Imax.)

≤ 0.7 V

Reverse polarity protection

conditional U

B

(the output 3 or 4 switch

must never be set directly to minus)

Anti-inductive protection

1 kV, 0.1 ms, 1 kΩ

Oscillator frequency

approx. 1000 kHz

Electromagnetic compatibility

(EMC)

per EN 60947-5-2

Ambient conditions and

temperature

in accordance with measuring instrument

Permissible ambient tempe-

ratures

-25 ... +70 °C

(depends on the basic instrument and is

found in the respective data sheet)

Installation

installed directly in the measuring instru-

ment at the factory, maximum 2 switch

contacts per measuring instrument

Ingress protection

per DIN EN 60529

(depends on the basic instrument and is

found in the respective data sheet)

For further specifications see WIKA data sheet AC 08.01 and the order

documentation.

4. Design and function

4.1 Description

Direct switching of small capacities which are usually required in connection

with a PLC can be realised by this inductive contact with integrated amplifier

which is factory-installed directly into the measuring instrument.

3. Specifications / 4. Design and function

Advertising
This manual is related to the following products: