INSTRUCTION SHEET 05603C-90

REV: B021608

MODEL 05603C

WIND SENSOR INTERFACE

0-5 VDC OUTPUT

R. M. YOUNG COMPANY

2801 Aero Park Drive, Traverse City, Michigan 49686 USA

TEL: 231-946-3980 FAX: 231-946-4772

SPECIFICATIONS

Power Requirement:

8-24 VDC (5 mA @ 12 VDC)

Temperature Range:

-50 to 50°C (-58 to 122°F)

Inputs:

YOUNG Wind Monitor series of sensors

Wind Speed

AC sine wave, Frequency proportional to
wind speed. 3 pulses per revolution. Input
sensitivity nom. 40 mV p-p

Wind Direction

Analog voltage from azimuth potentiometer.
Excitation is supplied from interface circuit to
potentiometer.

Outputs:

Wind Speed

0 to 5.00 VDC = 0 to 100 M/S
Circuit time constant 0.2 second

Wind Direction

0 to 5.00 VDC = 0 to 360°

Overall accuracy:

± 1% of full scale over temperature and
supply voltage range

Dimensions:

110 mm W x 75 mm H x 56 mm D
(4.3 in W x 2.9 in H x 2.2 in D)

Mounting:

U-bolt for vertical pipe 25-50mm (1.2 in) Dia

Declaration of Conformity

Application of Council Directives:

89/336/EEC

Standards to which Conformity is Declared:

EN 50082-1 (IEC 801-2, 3, 4)

Manufacturer's Name and Address:

R. M. Young Company
Traverse City, MI, 49686, USA

Importer's Name and Address:

See Shipper or Invoice

Type of Equipment:

Meteorological Instruments

Model Number / Year of Manufacture:

05603B/1996

I, the undersigned, hereby declare that the equipment
specified conforms to the above Directives and Standards.

Date / Place:

Traverse City, Michigan, USA February 19, 1996

David Poinsett
R & D Manager, R. M. Young Company

INTRODUCTION

The Wind Sensor Interface provides calibrated analog DC voltage
signals for wind speed and wind direction. The unit consists of a
circuit board assembly in a weather resistant junction box. All
cable connections are made in the junction box. See wiring
diagram below.

IMPORTANT!
The Wind Sensor Interface provides a calibrated
voltage output signal for wind speed and wind
direction. Externally connected devices should be
reviewed for compatibility and correct signal scaling.

Repairs should be attempted only by qualified service personnel.

WARRANTY

This product is warranted to be free of defects in materials and
construction for a period of 12 months from date of initial
purchase. Liability is limited to repair or replacement of defective
item. A copy of the warranty policy may be obtained from R. M.
Young Company.

CE COMPLIANCE

This product has been tested and shown to comply with European
CE requirements for the EMC Directive. Please note that shielded
cable must be used.