Young Sensors Relative Humidity & Temperature Probes Models 41382VF User Manual

Young Sensors

Advertising
background image

7.4in

188mm

5.4in

136mm

.94in

24mm

2.5in

62mm

3.4in

86.5mm

FILTER

MODEL 41382VF

RELATIVE HUMIDITY

/

TEMPERATURE PROBE

with VOLTAGE OUTPUT

INSTRUCTION SHEET 41382VF-90

REV E102613

R. M. YOUNG COMPANY

2801 Aero Park Drive , Traverse City, Michigan 49686 USA

TEL (231) 946-3980 FAX (231) 946-4772

I

NTRODUCTION

The Model 41382VF Relative Humidity/Temperature Probe combines

high accuracy humidity and temperature sensors in a single probe.

The output signal is 0-1 V (standard) or 0-5 V (user selected option)

for both relative humidity and temperature. RH range is 0-100%.

Temperature range is -50 to +150°F.

INSTALLATION

Install the probe in a naturally ventilated or fan aspirated radiation

shield. Mount probe and shield in a location with good air circulation

clear of large thermal masses (buildings, pavement, solar panels,

etc.), exhaust vents, electrical machinery and motors, water fountains

and sprinklers.

Set 0-1 V or 0-5 V output with jumpers

as shown in diagram. These jumpers are

located below the terminals in the junction

box.

MAINTENANCE

The probe provides years of service with minimal maintenance.

Humidity calibration, which may drift slightly with time, can be checked

or restored at the factory.

Periodically clean the humidity sensor filter when used in areas of

high dust or contamination (smokestacks, seawater, etc.) Soak in
clean water or use a mild soap solution. DO NOT USE SOLVENTS.

CE COMPLIANCE

This product complies with the European CE directive on EMC

compatibility. Shielded cable must be used.

WARRANTY

This product is warranted to be free of defects in materials and

construction for a period of 12 months from date of initial purchase.

Liability is limited to repair or replacement of defective item. A copy

of the warranty policy may be obtained from R. M. Young Company.

SPECIFICATIONS

RELATIVE HUMIDITY:

Measuring range:

0-100% RH

Accuracy at 73°F:

±1%

Stability:

Better than ±1% RH per year

Response Time:

10 seconds (Without Filter)

Sensor type:

Rotronic Hygromer

TEMPERATURE:

Measuring Range:

-50 to +150°F

Accuracy at 73°F:

±0.5°F

Response Time:

10 seconds (Without Filter)

Sensor type:

Platinum RTD

W

Output signal:

0-1 or 0-5 VDC (jumper option)

Power Required:

8-30 VDC at 7 mA

Recommended Cable:

5 conductor shielded, Young 18446

Recommended Shields:

Young Model 43502 Aspirated Radiation Shield

Young Model 41003P Multi-Plate Radiation Shield

Declaration of Conformity

R. M. Young Company

2801 Aero Park Drive

Traverse City, MI 49686 USA

Model 41382VF RH/Temp Probe

The undersigned hereby declares on behalf of R. M. Young

Company that the above-referenced product, to which this

declaration relates, is in conformity with the provisions of:

Council Directive 2004/108/EC (December 15, 2004)

on Electromagnetic Compatibility

David Poinsett