Overview, 3 warranty, 4 packing list – Next Advance SP1800 User Manual

Page 7: Features

Advertising
background image

NEXT>>>ADVANCE

www.nextadvance.com

SP1600/1800 Programmable Syringe Pump

Publication #1200-02

2

9/15/04

1.3 Warranty

Next Advance, Inc. warranties this product, and accessories for a period of two years, parts and labor,
from the date of purchase. The repaired unit will be covered for the period of the remainder of the original
warranty or 90 days, whichever is greater.

A return authorization number must be obtained from Next Advance before returning a unit for repair.
Warranty covered repairs will not be performed without a return authorization number. At the option of
Next Advance, Inc., a defective unit will be either repaired or replaced.

This warranty does not cover damage by any cause including, but not limited to, any malfunction, defect
or failure caused by or resulting from unauthorized service or parts, improper maintenance, operation
contrary to furnished instructions, shipping or transit accidents, modifications or repair by the user, harsh
environments, misuse, neglect, abuse, accident, incorrect line voltage, fire, flood, other natural disasters,
or normal wear and tear. Changes or modifications not approved by Next Advance, Inc. could void the
warranty.

The foregoing is in lieu of all other expressed warranties and Next Advance, Inc. does not assume or
authorize any party to assume for it any other obligation or liability.

1.4 Packing List

Included with the SP1600/SP1800 Programmable Multi-Syringe Pump are the following items:

One of the following external unregulated power supply adapters:

Input: 120V AC 60 Hz, 220V AC 50 Hz, 240V AC 50 HZ,

or other custom specified power supply

Output: 12V DC @ 1000 mA

This Operating Manual

2. Overview

The SP1600/SP1800 is a general purpose multi-syringe pump capable of infusion and withdrawal. The
model SP1600 will hold up to 6 syringes of up to 60 cc each. The model SP1800 will hold up to 8
syringes of up to 10 cc each.

The syringe pump is controlled from a microcontroller based system which drives a step motor, allowing a
large range of pumping rates configured to the inside diameter of the loaded syringes. The syringes are
driven from a drive-screw and drive-nut mechanism.

Features:

 Pumping rates from 5.832 l/hr to 1337

ml/hr (model SP1600) or 378 ml/hr (model
SP1800), depending on the syringe
diameter.

 Stall detection: The pump automatically

stops when the pumping is impeded

 Infusion and withdrawal volumes separately

accumulated.

 Programmable dispense volumes.
 Non-volatile memory of all operating

parameters and Pumping Program

 Programmable Phases allowing complex

pumping applications and interaction with
external devices.

 RS-232 bi-directional computer control.

 Built-in pump network driver. Pump

network supports up to 100 pumps and
other devices.

 Two modes of RS-232 control, Basic and

Safe. Safe mode provides communication
error detection, loss of communication
detection, and automatic transmitting of
alarm conditions.

 TTL I/O with software filtered control

inputs to eliminated glitches and ringing on
the control inputs.

 Configurable TTL operational trigger.
 Power Failure Mode: Restarts the Pumping

Program after a power interruption.

 Audible Alarm

Advertising