AN346

5

3.1

Decoupling of Sensitive Pins for CS1501

PFC Controllers have certain pins that are considered noise sensitive. For the CS1501 these are:

– Pin 1

IFB

– Pin 3

IAC

– Pin 4

CS (Current Sense)

– Pin 5

ZCD (Zero Current Detect)

Care must be taken to route these signals away from noise sources. The following table shows the
recommended decoupling capacitors for each pin. Figure 5 shows good decoupling practices. These
traces must be as narrow as possible because the currents carried by them are on the order of 1 A. Wide
traces are prone to the capacitive coupling of noisy signals.

Table 1. Recommended Decoupling for CS1501

Figure 5. Decoupling Layout for CS1501 Sensitive Signals

Pin

Number Designator

Recommended

Decoupling

1 IFB

1nF high-frequency ceramic capacitor recommended between pin 1
and GND or VDD.

2 STBY

Pull high through a resistor as shown in schematic. A 1nF decoupling
capacitor to ground is recommended if the pin is not used.

3 IAC

1nF high-frequency ceramic capacitor recommended between pin 3
and GND or VDD.

4 CS

100pF to 1nF high-frequency capacitor recommended between pin 4
pin and GND, depending on noise injection.

5

ZCD

33pF high-frequency ceramic capacitor between pin 5 and GND.

8 VDD

4.7uF high-frequency ceramic capacitor between pin 8 and GND. It is
highly recommended to place this capacitor directly between the pins
of CS1501. If VDD is generated from the 2

nd

stage DC-DC, a 10 to

100 ohm resistor in series with VDD will further reduce noise.