Parameter descriptions, Figure 10. parameter configuration sets, 1 modal configuration sets – Cirrus Logic CS2200-OTP User Manual

Page 17: 1 r-mod selection (rmodsel[1:0]), Cs2200-otp, Di g ita l/p ll co re

Advertising
background image

CS2200-OTP

DS842F2

17

6. PARAMETER DESCRIPTIONS

As mentioned in

Section 5.1 on page 9

, there are two different kinds of parameter configuration sets, Modal and

Global. These configuration sets, shown in

Figure 10

, can be programmed in the field using the CDK2000 or pre-

programmed at the factory. Please see

“Programming Information” on page 21

for more details.

Figure 10. Parameter Configuration Sets

6.1

Modal Configuration Sets

There are four instances of each of these configuration parameters. Selection between the four stored sets
is made using the M[1:0] pins.

6.1.1

R-Mod Selection (RModSel[1:0])

Selects the R-Mod value, which is used as a factor in determining the PLL’s Fractional N.

Note:

This parameter does not take affect unless M2 pin is high and the M2Config[2:0] global param-

eter is set to ‘011’.

RModSel[1:0]

R-Mod Selection

00

Right-shift R-value by 1 (÷ 2).

01

Right-shift R-value by 2 (÷ 4).

10

Right-shift R-value by 3 (÷ 8).

11

Right-shift R-value by 4 (÷ 16).

Application:

“Ratio Modifier (R-Mod)” on page 11

M[1:0] pins

Modal Configuration Set #0

RModSel[1:0]

AuxOutSrc[1:0]

Modal Configuration Set #1

Ratio 1

RModSel[1:0]

AuxOutSrc[1:0]

Modal Configuration Set #2

Ratio 2

RModSel[1:0]

AuxOutSrc[1:0]

Modal Configuration Set #3

Ratio 3

RModSel[1:0]

AuxOutSrc[1:0]

00

01

10

11

Global Configuration Set

RefClkDiv[1:0]

ClkOutUnl

AuxLockCfg

M2Config[2:0]

Ratio 0

Di

g

ita

l/P

LL Co

re