2 ratio 0 - 3, 3 global configuration parameters, 1 aux pll lock output configuration (auxlockcfg) – Cirrus Logic CS2100-OTP User Manual

Page 21: 2 reference clock input divider (refclkdiv[1:0]), 2 ratio 0 - 3 6.3 global configuration parameters, Cs2100-otp

Advertising
background image

CS2100-OTP

DS841F2

21

6.1.2

Auxiliary Output Source Selection (AuxOutSrc[1:0])

Selects the source of the AUX_OUT signal.

Note:

When set to 11, the AuxLockCfg global parameter sets the polarity and driver type (

“AUX PLL

Lock Output Configuration (AuxLockCfg)” on page 21

).

6.2

Ratio 0 - 3

The four 32-bit User Defined Ratios are stored in the CS2100’s one time programmable memory. See

“Out-

put to Input Frequency Ratio Configuration” on page 14

and

“Calculating the User Defined Ratio” on

page 23

for more details.

6.3

Global Configuration Parameters

6.3.1

AUX PLL Lock Output Configuration (AuxLockCfg)

When the AUX_OUT pin is configured as a lock indicator (AuxOutSrc[1:0] modal parameter = ‘11’), this
global parameter configures the AUX_OUT driver to either push-pull or open drain. It also determines the
polarity of the lock signal. If AUX_OUT is configured as a clock output, the state of this parameter is dis-
regarded.

Note:

AUX_OUT is an unlock indicator, signalling an error condition when the PLL is unlocked. There-

fore, the pin polarity is defined relative to the unlock condition.

6.3.2

Reference Clock Input Divider (RefClkDiv[1:0])

Selects the input divider for the timing reference clock.

AuxOutSrc[1:0]

Auxiliary Output Source

00

RefClk.

01

CLK_IN.

10

CLK_OUT.

11

PLL Lock Status Indicator.

Application:

“Auxiliary Output” on page 17

AuxLockCfg

AUX_OUT Driver Configuration

0

Push-Pull, Active High (output ‘high’ for unlocked condition, ‘low’ for locked condition).

1

Open Drain, Active Low (output ‘low’ for unlocked condition, high-Z for locked condition).

Application:

“Auxiliary Output” on page 17

RefClkDiv[1:0]

Reference Clock Input Divider

REF_CLK Frequency Range

00

÷ 4.

32 MHz to 75 MHz (50 MHz with XTI)

01

÷ 2.

16 MHz to 37.5 MHz

10

÷ 1.

8 MHz to 18.75 MHz

11

Reserved.

Application:

“Internal Timing Reference Clock Divider” on page 11

Advertising