Table 13. aes format detection, 9 rvcr status (address 08h) (read only) – Cirrus Logic CS42518 User Manual

Page 54

Advertising
background image

54

DS584F2

CS42518

6.9

RVCR Status (address 08h) (Read Only)

6.9.1

DIGITAL SILENCE DETECTION (DIGITAL SILENCE)

Default = x
0 - Digital Silence not detected
1 - Digital Silence detected
Function:

The CS42518 will auto-detect a digital silence condition when 1548 consecutive zeros have been de-
tected.

6.9.2 AES FORMAT DETECTION (AES FORMATX)

Default = xxx
Function:

The CS42518

will auto-detect the AES format of the incoming S/PDIF stream and display the infor-

mation according to the following table.

6.9.3

SYSTEM CLOCK SELECTION (ACTIVE_CLK)

Default = x
0 - Output of PLL
1 - OMCK
Function:

This bit identifies the source of the internal system clock (MCLK).

7

6

5

4

3

2

1

0

Digital Silence AES Format2 AES Format1 AES Format0

Active_CLK

RVCR_CLK2

RVCR_CLK1

RVCR_CLK0

AES

Format2

AES

Format1

AES

Format0

Description

0

0

0

Linear PCM

0

0

1

DTS

-CD

0

1

0

DTS

-LD

0

1

1

HDCD

1

0

0

IEC 61937

1

0

1

Reserved

1

1

0

Reserved

1

1

1

Reserved

Table 13. AES Format Detection

Advertising