4 volume control (addresses 06h - 0bh), 5 mode control 2 (address 0dh), 1 soft ramp and zero cross control (szc) bit 6-7 – Cirrus Logic CS4360 User Manual

Page 33: Table 10. example digital volume settings, D 6.4.1, Cs4360

Advertising
background image

CS4360

DS517F2

33

6.4

VOLUME CONTROL (ADDRESSES 06H - 0BH)

6.4.1

MUTE (MUTE)

BIT 7

Default = 0

0 - Disabled
1 - Enabled

Function:

The Digital-to-Analog converter output will mute when enabled. The quiescent voltage on the output
will be retained. The muting function is affected, similar to attenuation changes, by the Soft and Zero
Cross bits. The MUTEC pin will become active during the mute period if the Mute function is enabled
for both channels in the pair.

6.4.2

VOLUME CONTROL (XX_VOL)

BIT 0-6

Default = 0

Function:

The Digital Volume Control registers allow independent control of the signal levels in 1-dB increments
from 0 to -119 dB. Volume settings are decoded as shown in Table 10. The volume changes are im-
plemented as dictated by the Soft Ramp and Zero Cross bits. All volume settings less than -119 dB
are equivalent to enabling the MUTE bit.

6.5

MODE CONTROL 2 (ADDRESS 0DH)

6.5.1

SOFT RAMP AND ZERO CROSS CONTROL (SZC)

BIT 6-7

Default = 10

00 - Immediate Change
01 - Zero Cross
10 - Soft Ramp
11 - Soft Ramp and Zero Cross

Function:

Immediate Change

When Immediate Change is selected all level changes will be implemented immediately in one step.

7

6

5

4

3

2

1

0

xx_MUTE

xx_VOL6

xx_VOL5

xx_VOL4

xx_VOL3

xx_VOL2

xx_VOL1

xx_VOL0

0

0

0

0

0

0

0

0

Binary Code

Decimal Value

Volume Setting

0001010

10

-10 dB

0010100

20

-20 dB

0101000

40

-40 dB

0111100

60

-60 dB

1011010

90

-90 dB

Table 10. Example Digital Volume Settings

7

6

5

4

3

2

1

0

SZC1

SZC0

CPEN

PDN

POPG

FREEZE

MCLKDIV

SNGLVOL

1

0

0

1

1

0

0

0

Advertising