Characteristics and specifications, Recommended operating conditions, Absolute maximum ratings – Cirrus Logic CS4362A User Manual

Page 8

Advertising
background image

8

DS617F2

CS4362A

2. CHARACTERISTICS AND SPECIFICATIONS

RECOMMENDED OPERATING CONDITIONS

(GND = 0 V; all voltages with respect to ground.)

ABSOLUTE MAXIMUM RATINGS

(GND = 0 V; all voltages with respect to ground.)

WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation

is not guaranteed at these extremes.

Parameters

Symbol Min Typ

Max

Units

DC Power Supply

Analog Power

Digital Internal Power

Serial Data Port Interface Power

Control Port Interface Power

VA

VD

VLS
VLC

4.75
2.37
1.71
1.71

5.0
2.5
5.0
5.0

5.25
2.63
5.25
5.25

V
V
V
V

Ambient Operating Temperature (power applied)

Commercial Grade (-CQZ)

Automotive Grade (-DQZ)

T

A

-40
-40

-
-

+85

+105

°

C

°

C

Parameters

Symbol

Min

Max

Units

DC Power Supply

Analog Power

Digital Internal Power

Serial Data Port Interface Power

Control Port Interface Power

VA

VD

VLS
VLC

-0.3
-0.3
-0.3
-0.3

6.0
3.2
6.0
6.0

V
V
V
V

Input Current

Any Pin Except Supplies

I

in

-

±10

mA

Digital Input Voltage

Serial Data Port Interface

Control Port Interface

V

IND-S

V

IND-C

-0.3
-0.3

VLS+ 0.4
VLC+ 0.4

V
V

Ambient Operating Temperature (power applied)

T

op

-55

125

°C

Storage Temperature

T

stg

-65

150

°C

Advertising