Characteristics and specifications, Specified operating characteristics, Absolute maximum ratings – Cirrus Logic CS4398 User Manual
Page 8: Specified operating conditions

8
DS568F1
CS4398
2. CHARACTERISTICS AND SPECIFICATIONS
(Min/Max performance characteristics and specifications are guaranteed over the Specified Operating Conditions.
Typical performance characteristics are derived from measurements taken at T
A
= 25
°C, VA = 5.0 V, VD = 3.3 V.)
SPECIFIED OPERATING CONDITIONS
(AGND = 0 V; all voltages with respect to ground.)
ABSOLUTE MAXIMUM RATINGS
(AGND = 0 V; all voltages with respect to ground.)
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation
is not guaranteed at these extremes.
Parameters
Symbol Min Typ
Max
Units
DC Power Supply
Analog power
Voltage reference
Digital power
Serial audio interface power
Control port interface power
VA
VREF
VD
VLS
VLC
4.75
4.75
3.1
1.7
1.7
5.0
5.0
3.3
3.3
3.3
5.25
5.25
5.25
5.25
5.25
V
V
V
V
V
Specified Temperature Range
-CZ & -CZZ
T
A
-10
-
70
°C
Parameters
Symbol
Min
Max
Units
DC Power Supply
Analog power
Voltage reference
Digital power
Serial audio interface power
Control port interface power
VA
VREF
VD
VLS
VLC
-0.3
-0.3
-0.3
-0.3
-0.3
6.0
6.0
6.0
6.0
6.0
V
V
V
V
V
Input Current
any pin except supplies
I
in
-
±10
mA
Digital Input Voltage
Serial audio interface
Control port interface
V
IN-LS
V
IN-LC
-0.3
-0.3
VLS+ 0.4
VLC+ 0.4
V
V
Ambient Operating Temperature (power applied)
T
A
-55
125
°C
Storage Temperature
T
stg
-65
150
°C