Installation – Duff-Norton EM1050-200 (TAP) User Manual

Page 4

Advertising
background image

4

2-1. Clevis

Connections

Refer to Fig. 1-1 for appropriate mounting

dimensions. The actuator should be connected with
.50 inch diameter steel clevis pins, or bolts with
enough unthreaded length to provide full clevis
support. Lightly grease clevis pins to prevent wear and
noise.

2-2. Motor

Capacitor

All AC units use permanent split capacitor motors

requiring an external motor run capacitor. Capacitor
ratings are listed below.

If actuators are never operated at more than 50% of

rated load, capacitance may be reduced by up to 33%,
resulting in lower current and motor operating
temperature.

2-3. Wiring Connections

All wiring connections for AC units can be made to the

terminal block under the motor cover. Refer to Fig. 2-1
for wiring schematic and Fig. 2-2 for Terminal Block
Connections.

Connections to DC units are made directly to motor

leads. Use wire adequate for the rated motor amps.

Section II

INSTALLATION

Voltage

Rating

Duff-Norton No.

115VAC 50uf,370VAC

SK6405-7-15

230VAC 15uf,440VAC

SK6405-7-14

TA500

Performance at Rated Load

TA1000

Performance at Rated Load