FIGURE 1-6. DIMENSIONS AND SPECIFICATIONS

Warning:

1. Some actuator external surface temperatures may reach 230°F at or near maximum
allowable duty cycle.

2. Do not operate actuator before setting limit switches.

3. Position hooded vent to prevent moisture and dirt from entering actuator (see instruction and

maintenance sheet).

4. The actuator is not recommended for use in applications where it can be jammed. Examples

of jamming include overtraveling the limit switches and jamming the nut and screw internally

at the extreme ends of the stroke, or driving the actuator against an immovable object and thus

overloading the actuator severely. Therefore consult Duff-Norton Engineering if jamming is

expected.

5. For fuse replacement use only Little fuse Part No. 511025 (5ag,

32 volt, 25 amp) medium acting fuses.

6. Do not place foreign objects in the fuse holder or use fuses not recommended by Duff-

Norton.