Miscellaneous – Argox OS-214 plus User Manual

Page 30

Advertising
background image

54

LED Indicators: Power and Ready LEDs blink alternately

Power LED Ready LED
ON OFF
OFF ON

Possible Problems

Solutions

Remarks

Ribbon out

Supply the ribbon roll

Ribbon jam

Recover the jam

Ribbon sensor error Replace ribbon sensor

Not applicable to
direct thermal
type.



LED Indicators: Only the Power LED blinks

Power LED Ready LED
ON ON
OFF ON

Possible Problems

Solutions

Remarks

Serial IO error

Check the baud rate

Not for Centronics

Memory full

Add the extension RAM

Cutter failed, or jam
at cutter

Check the cutter
Recover the jam

Occurs only when
installing or setting the
cutter

Hardware error

Call for service


55

Miscellaneous


If the host shows "Printer Time out"

1. Check if the communication cable (parallel or serial) is

connected securely to your parallel or serial port on the
PC and to the connector on the printer at the other end.

2. Check if the printer power is turned on.


If the power cord is connected, the power switch is at position "I"
and the power LED is still not illuminated, check the fuse inside
the power adapter case.

If the data has been sent, but there is no output from the printer.
Check the active printer driver, and see if Label Dr. for your
Windows system and the label printer has been selected.

Vertical streaks in the printout usually indicate a dirty or faulty
print head. (Refer to the following examples.)










Advertising