This unit is to be used on a flat, level surface. If this unit has controls and

drains they need to be accessible at all times of operation. If the unit has a

vent the vent needs to face an open area so that air can circulate.
NOTE:

Do move the unit by pushing or pulling on the breath guard.

There must be a minimum of 24” (61 cm) of space between one side of

solid surfaces and on two sides for heating units.

There must be a minimum of 24” (61 cm) of space between the vents

and any solid surfaces for units with vents.

Sufficient airflow must be allowed around the unit. Blocking the airflow

could cause the unit to overheat.

o

Peration

WARNING

Burn Hazard.

Do not touch heating surfaces, liquid, or food while

unit is heating or operating.

Hot food, steam and liquids can burn skin. Allow the hot liquid,

spillage pans and trays to cool before handling. Use gloves, mitts or

pot holders if it is necessary to handle hot pans.

WARNING

Electrical Shock Hazard.

Keep water and other liquids from entering the

inside of the unit. Liquid inside the unit could cause

an electrical shock. Do not damaged power cord.

Do not over fill wells, pans or trays. Liquid could contact the

electrical components and cause a short circuit or an electrical

shock. Unplug unit before performing service, draining or removing

spillage pans and trays. Do not spray water or cleaning products.

Do not use a power cord that has been modified or damaged.

d

eluxe

H

ot

S

tAtion

C

ontrolS

And

o

PerAtion

10

9

8

7

6

5

4

3

2

1

0

H

A

D

D

F

E

G

B

C

I

Figure 2. Deluxe Hot Station Controls

A

ON/OFF switch. Set switch to the up position for “ON”. Set

switch to the down position for “OFF”. The switch will illuminate

when in the “ON” position.

B

ACCESS DOOR for drain valve. Open or remove to access the

drain valve.

C

DRAIN VALVE. Used to empty water from the well(s).

D

WATER LEVEL MARKS. Used to indicate the correct water

level.

E

TEMPERATURE CONTROL dial. Used to set or adjust the

temperature of the well. The larger the number the higher the

temperature, the smaller the number the lower the temperature.

The “0” position is off.

F

DIAL REFERENCE indicator. Used to show what position the

temperature control is set at.

G

LOW WATER light. Illuminates when the well needs water. If

the light illuminates during operation, clean fresh water must be

added to the well.

H

DRAIN VALVE CLOSED position. When the valve is in this

position the drain is closed.

I

DRAIN VALVE OPEN position. When the valve is in this

position the drain valve is open.