Vollrath CF101 User Manual

Page 12

Advertising
background image

6

B.

Product Selector Switch

The product selector switch changes the
refrigeration profile to allow two different products
to be made. Before the machine is in ready mode,
this switch can be moved to the desired profile.

C.

PUSH TO FREEZE Button

The PUSH TO FREEZE button is used to initiate
the run mode. To start the machine, place the Main
Freezer Power OFF-ON switch in the ON position
and press the PUSH TO FREEZE button.

D.

LEDs

The membrane switch features two lights; a green
LED and an amber LED. The green LED will flash
when the freezing cylinder is near ready mode
and stay lit during ready mode. The amber LED is
lit during standby, purge and clean modes.

NOTE

If the machine enters an error condition, alternating
green and amber lights will flash. The LCD will dis-
play an error. Turn the Main Freezer Power OFF-
ON switch to the OFF position, correct the problem
(Refer to Troubleshooting in Section 4) and turn the
machine back on.

E.

PURGE/CLEAN Button

PURGE Mode - When the PURGE/CLEAN button
is pressed, the auger will rotate. A PURGE
message will display on the screen along with a 5
minute timer. Hopper refrigeration will continue to
run. When the timer gets to 0:00 and no other
buttons are pressed, the machine will go into
standby mode.

CLEAN Mode - During PURGE mode, if the
PURGE/CLEAN button is pressed and held for 3
seconds, the CLEAN mode will begin. The auger
will continue to rotate and hopper refrigeration will
stop.

F.

Mix Low Light Indicator

The MIX LOW message will appear on the LCD
display to alert the operator to a low mix condition.
The message will display when there is
approximately one gallon of mix left in the hopper.
When the MIX LOW message is displayed, refill
hopper immediately.

NOTE

Failure to refill hopper immediately may result in
operational problems.

G.

Menu Navigation Buttons

The Menu Navigation Buttons are primarily used
for machine calibration.

Selection Button (SEL) The SEL button is not
functional in the normal operation mode. This
button is only used by service technicians for
machine calibration.

Set Button (SET) The SET button is not functional
in the normal operation mode. This button is only
used by service technicians for machine calibration.

Left Arrow Button (

Õ) Pressing any button on the

control panel will automatically illuminate the
display. The backlight will turn off several seconds
after use. To keep the display constantly lit, press
and hold the left (

Õ) button for five seconds. The

backlight function can be reset to normal operation
in the same manner.

Up Arrow Button (

×

) The

×

button is not

functional in the normal operation mode. This
button is only used by service technicians for
machine calibration.

H.

Front Door Safety Switch

The front door safety switch prevents the auger
from turning when the front door is removed. The
switch is open when the door is not in place and
closed when the door is properly installed.

3.3 SANITIZING

Sanitizing must be done after the machine is cleaned and
just before the hopper is filled with mix. Sanitizing the night
before is not effective. However, you should always clean
the machine and parts after each use.

THE UNITED STATES DEPARTMENT OF AGRICUL-
TURE AND THE FOOD AND DRUG ADMINISTRA-
TION REQUIRE THAT ALL CLEANING AND
SANITIZING SOLUTIONS USED WITH FOOD
PROCESSING EQUIPMENT BE CERTIFIED FOR
THIS USE.

When sanitizing the machine, refer to local sanitary regu-
lations for applicable codes and recommended sanitizing
products and procedures. The frequency of sanitizing
must comply with local health regulations.

Figure 3-2 IntelliTec Control

Push to Freeze

Green LED

Amber LED

SEL Button

SET Button

Purge/Clean
Button

Up Arrow Button

Left Arrow Button

Advertising