Vollrath CF101 User Manual

Page 18

Advertising
background image

12

necessary. Although this procedure may not be
needed on a daily basis, it will usually follow the
cleaning procedure. It requires letting a delimer
solution soak in the machine for an extended
period. Individual parts are also soaked in a
deliming solution for an extended period (more
about delimers in Additional Information).

3.

SANITIZING – After the machine has been cleaned
and contains no milkstone, the machine is
reassembled. Then a FDA-approved sanitizing
solution is run through the machine to kill bacteria.
The machine is then ready for food preparation.

As a recommended cleaner and sanitizer for your frozen
dessert machine, STERA-SHEEN has proven to be one of
the best daily maintenance products for:

CLEANING – Thorough removal of all solids

including butterfat and milk fat.

MILKSTONE REMOVAL – Complete removal of

milkstone.

SANITIZING – FDA-approved no rinse sanitizer

for food contact surfaces.

ADDITIONAL INFORMATION

THE USE OF DELIMERS

A delimer is a strong acid that has the ability to dissolve
milkstone. This type of chemical may become necessary
once high levels of milkstone have developed. While
these products are very effective for removing HIGH
levels of milkstone, they are not ideal for two reasons:

1.

PRODUCT SAFETY – Strong acids are dangerous
chemicals and handling them requires safety

2.

MACHINE DAMAGE – Strong acids will attack
metal and rubber causing premature wear of
parts. The use of a delimer needs to be closely
monitored to avoid damage to machine surfaces
and parts.

With proper daily use of STERA-SHEEN or its equivalent,
there is no need for the use of a DELIMER.

DO NOT USE BLEACH

BLEACH HAS ABSOLUTELY NO CLEANING

PROPERTIES.

BLEACH IS CORROSIVE. It can and will damage

components of the machine causing premature wear and
metal corrosion.

GENERAL PURPOSE CLEANERS

General purpose cleaners do not have the ability to re-
move milkstone. Milkstone will become a problem if not
remedied with additional products and procedures.

THE USE OF CHLORINE TEST STRIPS

“Test strips” are used to determine concentrations of
active chlorine in sanitizing solutions. To use the strips,
tear off a small portion and submerge it into the sanitizing
solution. Then, compare the color change to the color key
on the side of the test strip dispenser to determine the
approximate chlorine concentration.

The ideal concentration of chlorine needs to be 100 ppm
(as stated by the FDA).

NOTE

Follow the directions on the container for proper con-
centration.

There are two main factors that contribute to falling chlo-
rine concentrations in a sanitizing solution.

1.

PRODUCT USE – As the chlorine in the solution
is being used, chlorine concentrations fall.

2.

TIME – As time passes, small amounts of chlorine
“evaporate” from the solution. (That is why you
can smell it.)

Sanitizing solutions should not be allowed to fall below 100
ppm chlorine. New solutions should be mixed once old
solutions become ineffective.

3.13 EXTENDED STORAGE

Refer to the following steps for storage of the machine over
any long shutdown period:

A.

Turn the Main Freezer Power OFF-ON switch to
the OFF position.

B.

Disconnect (unplug) from the electrical supply
source.

C.

Clean thoroughly with a warm water detergent all
parts that are exposed to the mix. Rinse in clean
water and dry parts. Do not sanitize.

NOTE

Do not let the cleaning solution stand in the hopper
or in the machine barrel during the shutdown period.

D.

Remove, disassemble and clean the faceplate,
flow control assembly and auger parts. Place the
auger blades and the front auger wear bushing in
a plastic bag with a moist paper towel to prevent
them from becoming brittle.