8

Figure 5

Mix Pump Operation

ROLLER

COVER/CLAMP

3-WAY TEE

INLET SIDE

Figure 6

Removing Parts

MIX PILLOW

D. Overpressure Relief: Excess pressure is relieved

backwards through the peristaltic mix pump and out
the pickup side of the mix pump hose. This will

occur only if the pressure switch fails to shut off the
pump motor.

3.4 CLEANING

The mix pump must be cleaned when changing mix or

whenever the freezer is shut off for an extended
period, such as overnight or on nonbusiness days. For
sanitary reasons, mix must not be allowed to remain in
the freezer lines or mix pump when the freezer is not
in operation.

NOTE

To clean the freezer, refer to the freezer owner’s

manual for complete cleaning procedures.

1. Place the CLEAN-OFF-ON switch in the clean

position and agitate 5-10 minutes maximum.

2. Remove suction tube from mix container. Draw off

the mix remaining in freezer barrel.

3. Pump 2 gallons (7.5 liters) of cold potable water thru

freezer until water at spigot is free of mix.

4. Pump 2 gallons (7.5 liters) of 120ºF detergent solution

water thru freezer. The use of soft water is recom-
mended, along with dishwashing detergents such as
“Joy,” “Dawn,” or equivalent.

5. Place mix pump switch in OFF position. Open spigot

to relieve remaining pressure.

6. Place the CLEAN-OFF-ON switch in the OFF posi-

tion.

3.5 DISASSEMBLY AND INSPECTION OF
REMOVABLE PARTS

Inspection of removable parts should be made whenever
maintenance is performed or pump requires disassembly.

WARNING

Hazardous Moving Parts
Revolving pump head can grab, mangle, and cause
serious crushing injury. The Power switch must be
placed in the OFF position for cleaning and power
must be disconnected when disassembling or
servicing.