Lenovo ThinkServer TD100x User Manual

Page 79

Advertising
background image

Table

5.

Abbreviated

list

of

POST

error

codes

(continued)

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Error

code

Description

Action

162

Invalid

configuration

information

or

CMOS

random-access

memory

(RAM)

checksum

failure.

1.

Run

the

Configuration/Setup

Utility

program,

select

Load

Default

Settings,

and

save

the

settings.

2.

Reseat

the

following

components:

a.

Battery

b.

Failing

device

(If

the

device

is

a

FRU,

it

must

be

reseated

by

a

trained

service

technician

only.)

3.

Replace

the

following

components

one

at

a

time,

in

the

order

shown,

restarting

the

server

each

time:

a.

Battery

b.

Failing

device

(If

the

device

is

a

FRU,

it

must

be

replaced

by

a

trained

service

technician

only.)

c.

(Trained

service

technician

only)

System

board

163

The

time

of

day

has

not

set.

1.

Run

the

Configuration/Setup

Utility

program,

select

Load

Default

Settings,

make

sure

that

the

date

and

time

are

correct,

and

save

the

settings.

2.

Reseat

the

battery.

3.

Replace

the

following

components

one

at

a

time,

in

the

order

shown,

restarting

the

server

each

time:

a.

Battery

b.

(Trained

service

technician

only)

System

board

175

Service

processor

flash

code

damaged

or

not

loaded.

Note:

In

this

case,

the

service

processor

is

the

optional

Remote

Supervisor

Adapter

II

SlimLine.

1.

Update

the

Remote

Supervisor

Adapter

II

SlimLine

firmware

(see

the

Hardware

Maintenance

Manual).

2.

Replace

the

Remote

Supervisor

Adapter

II

SlimLine.

3.

(Trained

service

technician

only)

Replace

the

system

board.

178

System

VPD

not

available.

1.

Restart

the

server.

2.

Update

the

BMC

firmware

(see

the

Hardware

Maintenance

Manual.

3.

(Trained

service

technician

only)

Reseat

the

microprocessor.

4.

(Trained

service

technician

only)

Replace

the

microprocessor.

Chapter

5.

Solving

problems

63