Lenovo ThinkServer TD100x User Manual

Page 83

Advertising
background image

Table

5.

Abbreviated

list

of

POST

error

codes

(continued)

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Error

code

Description

Action

1800

Unavailable

PCI

hardware

interrupt.

1.

Run

the

Configuration/Setup

Utility

program

and

adjust

the

adapter

settings.

2.

Remove

each

adapter

one

at

a

time,

restarting

the

server

each

time,

until

the

problem

is

isolated.

1801

A

PCI

adapter

has

requested

memory

resources

that

are

not

available.

1.

Make

sure

that

no

devices

have

been

disabled

in

the

Configuration/Setup

Utility

program.

2.

Change

the

order

of

the

adapters

in

the

PCI,

PCI-X,

and

PCI

Express

slots.

Make

sure

that

the

startup

(boot)

device

is

positioned

early

in

the

scanning

order.

(For

information

about

the

scanning

order,

see

the

User

Guide

on

the

ThinkServer

Documentation

DVD.

3.

Make

sure

that

the

settings

for

the

adapter

and

all

other

adapters

in

the

Configuration/Setup

Utility

program

are

correct.

If

the

memory

resource

settings

are

not

correct,

change

them.

4.

If

all

memory

resources

are

being

used,

remove

an

adapter

to

make

memory

available

to

the

adapter.

Disabling

the

BIOS

on

the

adapter

should

correct

the

error.

See

the

documentation

that

comes

with

the

adapter.

1810

PCI

error.

1.

Make

sure

that

no

devices

have

been

disabled

in

the

Configuration/Setup

Utility

program.

2.

Reseat

the

failing

adapter.

Note:

If

an

error

LED

is

lit

on

an

adapter,

reseat

that

adapter

first;

if

no

LEDs

are

lit,

reseat

each

adapter

one

at

a

time,

restarting

the

server

each

time,

to

isolate

the

failing

adapter.

3.

Replace

the

following

components

one

at

a

time,

in

the

order

shown,

restarting

the

server

each

time:

a.

Failing

adapter

b.

(Trained

service

technician

only)

System

board

Chapter

5.

Solving

problems

67

Advertising
This manual is related to the following products: