Diskette drive problems, General problems, Hard disk drive problems – Lenovo ThinkServer TD100x User Manual

Page 90: Diskette, Drive, Problems, General, Hard, Disk

Advertising
background image

Diskette

drive

problems

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Symptom

Action

The

optional

diskette

drive

activity

LED

stays

lit,

or

the

server

bypasses

the

diskette

drive.

v

If

there

is

a

diskette

in

the

drive,

make

sure

that:

The

diskette

drive

cables

are

correctly

and

securely

connected.

The

diskette

drive

is

enabled

in

the

Configuration/Setup

Utility

program.

The

diskette

is

good

and

not

damaged.

(Try

another

diskette

if

you

have

one.)

The

diskette

is

inserted

correctly

in

the

drive.

The

diskette

contains

the

necessary

files

to

start

the

server.

Your

software

program

is

working

properly.

v

To

prevent

diskette

drive

read/write

errors,

make

sure

that

the

distance

between

monitors

and

diskette

drives

is

at

least

76

mm

(3

in.).

If

the

problem

remains,

replace

the

internal

diskette

drive

(see

the

Hardware

Maintenance

Manual).

General

problems

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Symptom

Action

A

cover

lock

is

broken,

an

LED

is

not

working,

or

a

similar

problem

has

occurred.

If

the

part

is

a

CRU,

replace

it.

If

the

part

is

a

FRU,

the

part

must

be

replaced

by

a

trained

service

technician.

Hard

disk

drive

problems

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Symptom

Action

Not

all

drives

are

recognized

by

the

hard

disk

drive

diagnostic

test

(the

Fixed

Disk

Test).

Remove

the

drive

that

is

indicated

by

the

diagnostic

tests;

then,

run

the

hard

disk

drive

diagnostic

test

again.

If

the

remaining

drives

are

recognized,

replace

the

drive

that

you

removed

with

a

new

one.

The

server

stops

responding

during

the

hard

disk

drive

diagnostic

test.

Remove

the

hard

disk

drive

that

was

being

tested

when

the

server

stopped

responding,

and

run

the

diagnostic

test

again.

If

the

hard

disk

drive

diagnostic

test

runs

successfully,

replace

the

drive

that

you

removed

with

a

new

one.

74

ThinkServer

TD100

and

TD100x

Types

4203,

4204,

4205,

4206,

6398,

6399,

6419,

and

6429:

Installation

Guide