3 both sides density adjustment, 1 [01 both sides max. dens. manual, Both sides density adjustment – Konica Minolta bizhub PRESS 2250P User Manual

Page 49: 01 both sides max. dens. manual] -3, 3both sides density adjustment

Advertising
background image

bizhub PRESS 2250P

3-3

3.1

[01 Both Sides Max. Dens. Manual]

3

3

Both Sides Density Adjustment

3.1

[01 Both Sides Max. Dens. Manual]

The machine consists of Main Body 1 and Main Body 2, each printing the front side or back side. As a result,
there may be a difference in the density of the 2 main bodies. To eliminate the difference, you need to output
and check the respective chart sheets in maximum density and then manually adjust the density.

Patterns of the charts

Pattern 1:

Prints 2 chart sheets in total, one from each main body, using the maximum density value manually set.

Pattern 2:

Prints 10 chart sheets in total, 5 from each of the two main bodies using the maximum density value set to -
5, -3, -1, +1, and +3, regardless of the manually set value.

Objects of adjustment: Main Body 1 (Side 1), Main Body 2(Side 2)

Adjustable range: - 5 to + 3

1

Press [Adjustment] on the Machine Screen to display the Adjustment Menu Screen.

2

Press [07 Both Sides Density Adjustment] and [01 Both Sides Max. Dens. Manual] in sequence.

The Both Sides Maximum Density Manual Adj. Screen will be displayed.

3

Press [Print Mode].

A dialog box will be displayed to select a pattern of chart to be printed.

4

Select [Pattern 1] or [Pattern 2].

Advertising