Indications / charging modes – AEG Micro-Processor Charging Unit LP 3.8 User Manual

Page 17

Advertising
background image

17

GB

iNDiCatioNs /

CHargiNg moDEs

9 10 11

12

13

14

15

16

9

Charging mode 14.4 V / 0.8 a max
suitable for charging

small batteries < 14 ah

10

Charging mode 14.4 V / 3.8 a max
suitable for charging large batteries in

normal conditions (normally used for

WEt, mF and most gEL batteries).

11

Charging mode 14.7 V / 3.8 a max
suitable for charging large batteries

in sub-zero temperatures and several

agm batteries with capacity of more

than 14 ah.

12

Fault!
incorrect polarity

13

Fully charged

14

Charging in progress

15

Before charging mode selection and

in case of open circuit, short circuit or

reverse connection.

16

„mode“ selection button

Technical data

maximum

charging

capacity

3800 ma

Charging

characteristic

5-level (iiUoiUp characteristic)

For battery types gel, agm, lead acid,

maintenance-free and

low-maintenance batteries

Battery voltage

12 V

operating volt-

age

230 V aC

recommended

for battery

capacity

1.2 - 120 ah

Display

LED (charging progress etc.)

safety features

overloading, short circuit,

overheating and voltage reversal

protection as well as anti-spark

and electronic-proof (no damage

of sensitive on-board electronics)

Fuse
the (+) pole connector cable (red) with a ring con-

nector is secured with a flat plug-in fuse (10 a). it is

activated in the case of short circuits or voltage peaks

and must be replaced subsequently.
Change fuse:
Attention! Do not install a stronger fuse. otherwise

the electronics could be damaged.
1. open the protective casing

2. remove the defective flat plug-in fuse

3. insert a new flat plug-in fuse of the same size (10 a)

into the slot

4. Close the protective casing once again

Advertising