background image

45°

4. Hold the door with one hand on each

side and pull it away from the

appliance at an upwards angle.

5. Put the door with the outer side

down on a soft cloth on a stable

surface. This is to prevent scratches.

6. Hold the door trim (B) on the top

edge of the door at the two sides

and push inwards to release the clip

seal.

1

2

B

CAUTION!

Rough handling of the glass,

especially around the edges

of the front panel, can cause

the glass to break.

7. Pull the door trim to the front to

remove it.

8. Hold the door glass panels on their

top edge one by one and pull them

up out of the guide.

9. Clean the glass panel with water and

soap. Dry the glass panel carefully.

When the cleaning is completed, install

the glass panels and the door. Do the

above steps in the opposite sequence.

Install the smaller panel first, then the

larger.

12.6 Replacing the lamp

Put a cloth on the bottom of the interior

of the appliance. It prevents damage to

the lamp glass cover and the cavity.

WARNING!

Danger of electrocution!

Disconnect the fuse before

you replace the lamp.

The lamp and the lamp glass

cover can be hot.

1. Deactivate the appliance.

2. Remove the fuses from the fuse box

or deactivate the circuit breaker.

The top lamp

1. Turn the lamp glass cover

counterclockwise to remove it.

2. Remove the metal ring and clean the

glass cover.

3. Replace the lamp with a suitable 300

°C heat-resistant lamp.

4. Attach the metal ring to the glass

cover.

5. Install the glass cover.

The side lamp

1. Remove the left shelf support to get

access to the lamp.

2. Use a Torx 20 screwdriver to remove

the cover.

3. Remove and clean the metal frame

and the seal.

4. Replace the lamp with a suitable 300

°C heat-resistant lamp.

5. Install the metal frame and the seal.

Tighten the screws.

6. Install the left shelf support.