Cleaning the TTL connector

If the threaded sections of the TTL cable and TTL cable connector stick to each other, the cable may
disconnect from the connector. To prevent this, apply silicone grease, provided with this case to the
threaded sections.
For details, see “Maintenance of the TTL Connector Cap” (P. 34) of this manual.

How to connect the hot shoe cable

To perform TTL flash shooting using the Case, connect the hot shoe cable (optional) between the
connector on the Case and the digital camera’s hot shoe.

CAUTION:

If the TTL cable connector cap is loose, water penetration may result. Be sure to gently turn the cap until it
stops to make sure it is firmly secured.
Do not turn or tighten the TTL cable too hard. If it is too tight, it may be difficult to loosen and remove.

CAUTION:

If you cannot disconnect the TTL cable, do not use force. Contact Olympus for support.

1

Turn the hot shoe cable connector cap inside the case
counterclockwise to remove it.

2

Insert the connector of the hot shoe cable into the case’s
connector and turn the connector screws all the way
clockwise to connect them firmly.

3

Insert the hot shoe on the hot shoe cable into the hot shoe
on the camera.
The hot shoe cover removed from the camera can be
stored in the camera table.
For details, see “How to attach the camera table to the
digital camera” (P. 19) of t
his manual.

4

When not using the hot shoe cable, attach the hot shoe
cable cap to the hot shoe cable connector inside the case
and turn the cap all the way clockwise to attach it firmly.

CAUTION:

Be sure to remove the camera from the case when inserting the connector of the hot shoe cable into the
case’s connector.