POWER SUPPLY IS CURRENT LIMITED TO 1 AMP PER EVERY THREE ZONES

The six zone receiver has two zone/controller cards, each is identical to the single controller card in a three
zone receiver. Each card has its own independent 1 amp power supply with built in current limiting protection.
You cannot draw more than 1 amp from each of the cards (a card is the vertical strip of zone and common
control connections). The control outputs are current limited to 200mA.

CT310/300 has one power supply card for keypads, IR sensors and 12VDC control outs. Anything connected
to the +12V zone keypad output, a zone control out or a common control out must have its power consump-
tion noted and added up. The total must not draw more than 1 amp for a CT310/300.

12V Power Supply

B K

&

S

B

I M P LY

E T T E R !

16

ZB

ZE

+12V

GND

RS232 XMIT

CTRL OUT

DATA IN

ZC

ZF

+12V

GND

RS232 XMIT

CTRL OUT

DATA IN

CONTROL

ZA

ZD

+12V

GND

RS232 XMIT

DATA IN

CTRL OUT

21

RS232

12V

GND

IN

-

IN

-

OUT

IN +

12V

GND

IN

-

IN

-

OUT

IN +

COMMON
CTRL I/O

COMMON
CTRL I/O

OUT

LEFT CONTROL CARD

Fam Rm Keypad 75ma

Fam Rm Sensor 50ma

Fam Rm Screen Relay 200ma

Kitchen Keypad 75ma

Bedroom Keypad 75ma

Bedroom TV Lift 200ma

Total 675 ma

RIGHT CONTROL CARD

Liv Rm Keypad 75 ma

Patio Keypad 75 ma

Den Keypad 75 ma

Den Sensor 50 ma

Total 275 ma

Adding Additional Keypads in the Same Zone.

When rooms are interconnected or are open to each other (for example: interconnecting family room, kitchen,
and dining areas are common in many homes) you may opt to expand a zone to include several rooms.
Many keypads can be connected in a daisy chain from the master keypad in that zone. The master is the
keypad which is home run back to the CT Receiver. To daisy chain keypads, simply connect a CAT5 cable
terminated into RJ-45 between the two keypads. All the chained keypads need be programmed separately .
Daisy-chained keypads can be programmed for independent zone control using the appropriate code-set.

The home run (master) keypad is connected using the MASTER [IN] on the keypad back panel. From the
Master Keypad's SLAVE[OUT] connect to the second keypad's MASTER [IN]. You can continue the daisy-
chain to as many as four keypads per zone control terminal. When programming daisy chained keypads,
each keypad must be programmed separately. Always program chained keypads in series order start-
ing with the Master keypad, then the first slave, etc.