Troubleshooting

SmartTemp Ready Light does not illuminate.

Possible Causes

Remedies

The machine Power Switch is not

Switch must be ON to

turned ON.

activate the SmartTemp Ready Light.

Reduced spray or no spray

Possible Causes

Remedies

Bladder may be empty.

Refill bladder with hand hot tap water.

SmartMix Bottle may be empty.

Fill with BISSELL Advanced Deep Cleaning

Formula for cleaning or water

if

rinsing.

The Filter may be clogged.

Clean out Flow Indicator Filter, page 17.

Tanks may not be seated properly.

Turn Power Switch OFF; remove &

reseat tanks. Inspect for presence

of

seals.

Pump may have lost prime.

Turn Power Switch OFF; after 1 minute

turn ON and depress trigger.

The Pump Belt may be broken.

Turn Power Switch OFF and unplug

from the outlet. To check if a Pump

Belt has broken, you will need a flat

head screwdriver. Insert the blade end

into the lower slot of the Belt Access

Door to release the lower snap. If

necessary, insert the blade end into

the upper slot to release the upper

snap. Examine the belt for breakage.

You should be able to see the Pump

Belt looped around the motor shaft. If

it is broken or missing, please refer to

Replacement Parts on page 23 before

calling Consumer Services. Complete

installation instructions will

accompany the Replacement Belt.

Insert
Screwdriver
Blade Here

Lift Here