Sharp UP-3500 User Manual

Page 42

Advertising
background image

41

You can specify whether to enable or disable the system retry function if a communication between
machines does not end successfully.
This function can be specified in the INLINE CONFIG window of the master and each satellite in the IRC system.

1.

Enter the PGM2 mode from the mode selection window.

2.

Select “2 SETTING” from the displayed menu.
The SETTING window will appear.

3.

Select “21 INLINE CONFIG” from the displayed menu.
The INLINE CONFIG window will appear.

4.

Touch the “SYSTEM RETRY” line and select “ENABLE” or “DISABLE”, and then touch the [CONTINUE]
key to complete the setting. (The following is applied only in the case of the setting at the master.)
The MASTER LIST window will appear.

5.

Touch the [CONTINUE] key again to close the MASTER LIST window.

• If the system retry function is enabled, a transmission job with which an error has occurred is

not finalized immediately, but the master waits for selection of one of the three commands
(RETRY, ABORT and IGNORE). Then the master retries access to the satellite that has
caused the transmission error or terminates the access as a successful or unsuccessful
transmission depending on the selection made.

• If the function is disabled, the job is terminated immediately.
• For further information, see the “System retry function” section on pages 55–56.
• The default setting is “ENABLE.”

At a satellite, you can choose which machine, either the master or the satellite, should be searched first for
the PLU/EAN code. If you specify that the master should be searched first and enter the PLU/EAN code, the
master is first searched and then the satellite is searched, and vice versa.
However, either choice of search order made at the master is invalid. In other words, even if you specify at
the master that the satellite should be first searched, the master will be first searched.

1.

Enter the PGM2 mode from the mode selection window.

2.

Select “2 SETTING” from the displayed menu.
The SETTING window will appear.

3.

Select “21 INLINE CONFIG” from the displayed menu.
The INLINE CONFIG window will appear.

4.

Touch the “LOOKUP ORDER” line and select “MA” or “SA”, and then touch the [CONTINUE] key.

6. Choosing whether to search the master or satellite

first for the PLU/EAN code – satellite

NOTE

5. Specifying whether to enable or disable the system retry function

when a transmission error occurs – master and satellite