Installation

WS-1X

Bradley Corporation • 215-1441 Rev. C; EN 07-304

4/2/07

3

1

Rough-In Piping

Supply inlets are 1/2" NPT fl exible hose and are accessible from the back of the shower or from knockouts on the top cover.
Bradley’s Equa-Flo valve shown; other valve versions install in similar manner.

If supplies will be run “thru-wall”, Bradley recommends using a 90° street ell to connect the supply hoses.

If supplies will be run “from above”, Bradley recommends running them approximately 1/2" into the top cover.

See table on page 2 for recommended
showerhead heights.

2

Install Shower

Shower Dimensions

Front

Rear

Hot

Cold

or

Tempered

Supplies

Thru

Wall

6-3/4"

(173)

4"

(102)

1/2"

(13)

5"

(127)

6"

(152)

4"

(102)

13-3/4"

(349)

3-1/8"

(80)

Supplies from above

22-3/4"

(579)

3-1/4"

(82)

1/2"

(12)

17-3/4"

(452)

6-7/8"

(173)

1/2"

(12)

1-3/4"

(44)

3-1/2"

(89)

16-3/4"

(425)

Using the shower hinge as a
template, mark wall and drill
holes for 1/4" fasteners (wall
anchors and fasteners
supplied by installer). Secure
hinge side to the wall.

A

Connect the 1/2" flexible hoses
to the supply lines. Turn the
water on and check for leaks
and adequate water spray.

B

Close the shower tight to
the wall and mark the
holes for the mounting
tabs on the wall. mark wall
and drill holes for 1/4"
fasteners. Secure tabs to
the wall.

C