Additional notes onoperation – Sharp AY-XPC9JR User Manual

Page 15

Advertising
background image

GB-13

ENGLISH

INDOOR TEMP.

OUTDOOR TEMP.

COOLING

upper limit

32˚C

46˚C (Single use)

43˚C (Multi use)

lower limit

21˚C

–10˚C (Single use)

21˚C (Multi use)

HEATING

upper limit

27˚C 24˚C

lower

limit – –15˚C

• The built-in protective device may prevent the unit

from operating when used out of this range.

• Condensation may form on the air outlet if the unit

operates continuously in the COOL or DRY mode

when humidity is over 80 percent.

WHEN POWER FAILURE OCCURS

This air conditioner has a memory function to store

settings when a power failure occurs.

After power recovery, the unit will automatically re-

start in the same settings which were active before

the power failure, except for timer settings.

If the timers were set before a power failure, they

will need to be re-set after power recovery.

PREHEATING FUNCTION

In the HEAT operation, the indoor fan may not start

for two to fi ve minutes after the unit is turned on to

prevent cold air from blowing out of the unit.

DE-ICING FUNCTION

• When ice forms on the heat exchanger in the

outdoor unit during the HEAT operation, an

automatic de-icer provides heat for about 5 to 10

minutes to remove the ice. During de-icing, the

inside and outside fans stop operating.

• After de-icing is completed, the unit automatically

resumes operation in the HEAT mode.

HEATING EFFICIENCY

• The unit employs a heat pump that draws heat

from the outside air and releases it into the room.

The outside air temperature therefore greatly

affects the heating effi ciency.

• If the heating effi ciency is reduced due to low

outside temperatures, use an additional heater.

• It takes time to warm up and heat the entire room

because of the forced air circulation system.

MAINTENANCE AFTER AIR

CONDITIONER SEASON

1

Operate the unit in the SELF CLEAN

operation to allow the mechanism to

thoroughly dry.

2

Stop the operation and unplug the unit.

Turn off the circuit breaker, if you have

one exclusively for the air conditioner.

3

Clean the fi lters, then reinstall them.

MAINTENANCE BEFORE AIR

CONDITIONER SEASON

1

Make sure that the air fi lters are not

dirty.

2

Make sure that nothing obstructs the

air inlet or outlet.

CHANGING THE AIR PURIFYING

FILTER

The fi lters should be changed every 3 ~ 6 months

1

Remove the air fi lters.

2

Change the air purifying fi lters.

1

Take off the old air purifying fi lters from the

air fi lters.

2

Set the new air purifying fi lters, under the

fi lter stoppers located on the air fi lters.

3

Reinstall the air fi lters.

NOTE:

• The dirty air purifying fi lters are not washable

for reuse. The new fi lters are available at your

nearest dealer.

Replacement fi lter: Type AZ-F920F

Disposal of Filters

Please dispose of replaced fi lters according to the

local disposal laws and regulations.
AIR PURIFYING fi lter materials

Filter:Polypropylene

Frame:Polyester

Filter stopper

ADDITIONAL NOTES ON

OPERATION

OPERATING TEMPERATURE RANGE