TYPICAL WIRING SCHEMATICS (cont)

LEGEND

AHA

—

Adjustable Heat Anticipator

C

—

Contactor Compressor

CAP

—

Capacitor

CB

—

Circuit Breaker

CC

—

Cooling Compensator

CDT

—

Compressor Discharge Thermostat

COMP

—

Compressor Motor

EQUIP

—

Equipment

FU

—

Fuse

GND

—

Ground

HPS

—

High-Pressure Switch

HR

—

Heater Relay

IFC

—

Indoor-Fan Contactor

IFM

—

Indoor-Fan Motor

IFR

—

Indoor-Fan Relay

JB

—

Junction Box

L

—

Light

LPS

—

Low-Pressure Switch

NS

—

Night Setback Switch

OAT

—

Outdoor-Air Thermostat

OFC

—

Outdoor-Fan Contactor

OFM

—

Outdoor-Fan Motor

PL

—

Plug Assembly

QT

—

Quadruple Terminal

RC

—

Run Capacitor

SW

—

Switch

TB

—

Terminal Block

TC

—

Thermostat-Cooling

TH

—

Thermostat-Heating

TRAN

—

Transformer

Marked Wire

Denotes connection point between
subbase and thermostat

Terminal (Marked)

Terminal (Unmarked)

Terminal Block

Field Splice

Splice (Marked)

Factory Splice

Factory Wiring

Accessory or Optional Wiring

Field Control Wiring

Field Power Wiring

To indicate common potential
only, not to represent wiring

502A024, 230-1-60 Units

NOTES:
1. Neutral for 240/416 v supply (Canada only).
2. If any original wires furnished must be replaced, it should be

replaced with 90 C or its equivalent.

3. Numbers indicate the line location of used contacts. A bracket

over 2 numbers signifies a single-pole double-throw contact. An
underlined number signifies a normally closed contact. Plain (no
line) number signifies a normally open contact.

4. Must use thermostat HH07AT170, 172 or 174 with subbase

HN63AZ176, 177 or 179.

5. Separate field power supply required for electric heater

accessory.