13 typical wiring schematics (cont) – Bryant CeilingPAC 502A User Manual

Page 13

Advertising
background image

13

TYPICAL WIRING SCHEMATICS (cont)

LEGEND

AHA

—

Adjustable Heat Anticipator

BKR W/AT —

Breaks with Amp Turns

C

—

Contactor Compressor

CC

—

Cooling Compensator

CLO

—

Compressor Lockout

COMP

—

Compressor Motor

CT

—

Current Transformer

EQUIP

—

Equipment

GND

—

Ground

HPS

—

High-Pressure Switch

IFC

—

Indoor-Fan Contactor

IFM

—

Indoor-Fan Motor

IFR

—

Indoor-Fan Relay

JB

—

Junction Box

L

—

Light

LOR

—

Lockout Relay

LPS

—

Low-Pressure Switch

NEC

—

National Electrical Code

OFM

—

Outdoor-Fan Motor

PL

—

Plug Assembly

PRI

—

Primary

TB

—

Terminal Block

TC

—

Thermostat-Cooling

TH

—

Thermostat-Heating

TRAN

—

Transformer

Marked Wire

Denotes connection point between
subbase and thermostat

Terminal (Marked)

Terminal (Unmarked)

Terminal Block

Field Splice

Splice (Marked)

Factory Splice

Factory Wiring

Accessory or Optional Wiring

Field Control Wiring

Field Power Wiring

To indicate common potential
only, not to represent wiring

502A048,060, 575-3-60 Units

NOTES:
1. Compressor and fan motors are thermally protected, three-phase

motors protected against primary single-phase conditions.

2. If any original wires furnished must be replaced, it should be

replaced with 90 C or its equivalent.

3. Numbers indicate the line location of used contacts. A bracket

over 2 numbers signifies a single-pole double-throw contact. An
underlined number signifies a normally closed contact. Plain (no
line) number signifies a normally open contact.

4. Must use thermostat HH07AT170, 172 or 174 with subbase

HN63AZ176, 177 or 179.

5. Neutral for 240/416 v supply (Canada only).
6. The CLO locks out the compressor to prevent short cycling on

compressor overloads and safety devices, before replacing CLO
check these devices.