Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for

your installation. Three close-clearance installations are shown.

Refer to the manufacturer’s instructions provided with the vent

system.

NOTE: The following kits for close clearance alternate installations

are available for purchase. Please reference the “Assistance or

Service” section of the Washer/Dryer User Instructions.

Over-the-Top Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent

mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch
Part Number 4396011 - 18" (457 mm) to 29" (737 mm)

mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1.27 m)

mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible

portion of the mobile home structure and must not terminate

beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most

direct path outdoors.
Plan the installation to use the fewest number of elbows

and turns.
When using elbows or making turns, allow as much room

as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90° turns possible.

Determine vent length and elbows needed for best drying

performance

Use the Vent system chart below to determine type of vent

material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in

the Vent system chart. Exhaust systems longer than those

specified will:

Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and

increased energy usage.

The Vent system chart provides venting requirements that will help

to achieve the best drying performance.

Vent system chart

NOTE: Side exhaust installations add a 90º turn inside the dryer.

To determine maximum exhaust length, add one 90º turn to the

chart.

A. Loop system with standard elbows

B. Loop system with one offset and one standard elbow
C. Vent system with one periscope (2" [51 mm] clearance)

A

B

C

Number of

90º turns

or elbows

Type of Vent

Box or

Louvered

hoods

Angled

hoods

0

Rigid metal

43 ft (13.1 m)

36 ft (11.0 m)

1

Rigid metal

33 ft (10.1 m)

26 ft (7.9 m)

2

Rigid metal

23 ft (7.0 m)

16 ft (4.9 m)