7

2. Remove neutral ground wire from internal ground conductor

screw. Connect neutral ground wire and the neutral wire (white

or center wire) of power supply cord under center silver-

colored terminal block screw. Tighten screw.

3. Move the green painted screw from the internal to the external

ground conductor location. Connect ground wire (green or

bare) of power supply cord to external ground conductor

screw. Tighten screw.

4. Connect the other wires to outer terminal block screws.

Tighten screws.

5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

7. You have completed your electrical connection. Now go to

“Venting Requirements.”

4-wire connection: Direct Wire

IMPORTANT: A 4-wire connection is required for mobile homes

and where local codes do not permit the use of 3-wire

connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so

washer/dryer can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving

bare ground wire at 5" (127 mm). Cut 1 " (38 mm) from

3 remaining wires. Strip insulation back 1" (25 mm). Shape ends

of wires into a hook shape.

When connecting to the terminal block, place the hooked end of

the wire under the screw of the terminal block (hook facing right),

squeeze hooked end together, and tighten screw. See example

below.

1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from internal ground conductor

screw. Connect neutral ground wire and place the hooked end

(hook facing right) of the neutral wire (white or center wire) of

direct wire cable under the center screw of the terminal block.

Squeeze hooked ends together. Tighten screw.

A. Center silver-colored terminal block screw
B. Neutral ground wire - Dotted line shows position of

NEUTRAL ground wire before being moved to center

silver-colored terminal block screw.

C. Internal ground conductor screw
D. Neutral wire (white or center wire)

E. ¾" (19 mm) UL listed strain relief

A. Neutral wire (white or center wire)
B. Center silver-colored terminal block screw

C. Neutral ground wire
D. External ground conductor screw

E. Ground wire (green or bare) of power supply cord
F. Internal ground conductor location

G. ¾" (19 mm) UL listed strain relief

A

B

C

D

E

A

B

C

D

E

F

G

A. Center silver-colored terminal block screw
B. Neutral ground wire

C. Internal ground conductor screw - Dotted line shows

position of NEUTRAL ground wire before being

moved to center silver-colored terminal block screw.

D. Neutral wire (white or center wire)

E. ¾" (19 mm) UL listed strain relief

1"

(25 mm)

5"

(127 mm)

A

B

C

D

E

1

2

Advertising