3-wire connection: Direct Wire

Use where local codes permit connecting cabinet-ground

conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so

washer/dryer can be moved if needed.
Strip 3 " (89 mm) of outer covering from end of cable. Strip

insulation back 1" (25 mm). If using 3-wire cable with ground wire,

cut bare wire even with outer covering. Shape ends of wires into a

hook shape.

When connecting to the terminal block, place the hooked end of

the wire under the screw of the terminal block (hook facing right),

squeeze hooked end together, and tighten screw.

1. Loosen or remove center silver-colored terminal block screw.
2. Place the hooked end of the neutral wire (white or center wire)

of direct wire cable under the center screw of terminal block

(hook facing right). Squeeze hooked end together. Tighten

screw.

3. Place the hooked ends of the other power supply cable wires

under the outer terminal block screws (hooks facing right).

Squeeze hooked ends together. Tighten screws.

4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

6. You have completed your electrical connection. Now go to

“Venting Requirements.”

Optional 3-wire connection

Use for direct wire or power supply cord where local codes do

not permit connecting cabinet-ground conductor to neutral

wire.
1.
Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from internal ground conductor

screw. Connect neutral ground wire and the neutral wire (white

or center wire) of power supply cord/cable under center

silver-colored terminal block screw. Tighten screw.

3. Connect the other wires to outer terminal block screws.

Tighten screws.

4. Tighten strain relief screws.
5. Move the green painted screw from the internal to the external

ground conductor location. Connect a separate copper

ground wire from the external ground conductor screw to an

adequate ground.

6. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

A. Neutral wire (white or center wire)
B. Center silver-colored terminal block screw

C. Neutral ground wire
D. Internal ground conductor screw

E. ¾" (19 mm) UL listed strain relief

1"

(25 mm)

3 "

(89 mm)

A

B

C

E

D

A. Neutral wire (white or center wire)
B. Neutral ground wire

C. External ground conductor screw
D. Grounding path determined by a qualified electrician

E. Internal ground conductor location