Whirlpool GXU7130DXS User Manual

Whirlpool Kitchen

Advertising
background image

PRODUCT MODEL NUMBERS

GXU7130DX

ELECTRICAL REQUIREMENTS

• A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

VENTING REQUIREMENTS

Vent system can terminate either through the roof or wall. Use 3

¹⁄₄" x 10" (8.3 x

25.4 cm) with a maximum vent length of 35 ft (10.7 m) or 6" (15.2 cm) or larger
round vent with a maximum length of 50 ft (15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and
air turbulence that gently reduce performance.

30" (76.2 CM) Range Hood

Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10320576A

10/20/10

®

Roof Venting

Wall Venting

A

B

D

C

E

A

B

C

D

E

A. 6" (15.2 cm) or larger round

vent or a 3

¹⁄₄" x 10" (8.3 x

25.4 cm) rectangular vent
through roof

B. Round vent: use 6" (15.2 cm)

or larger round damper
(purchased separately)

C. Round vent: use 3

¹⁄₄" x 10"

(8.3 x 25.4 cm) to 6" (15.2 cm)
or larger diameter transition
piece
(purchased separately)

D. 27" (68.6 cm) - 30" (76.2 cm)

above gas cooking surface
24" (61.0 cm) - 30" (76.2 cm)
above electric cooking
surface

E. Roof cap

A. 6" (15.2 cm) or larger round

vent or a 3

¹⁄₄" x 10" (8.3 x

25.4 cm) rectangular vent
through the wall

B. Round vent: use 3

¹⁄₄" x 10" (8.3

x 25.4 cm) to 6" (15.2 cm) or
larger diameter transition piece
(purchased separately)

C. 3

¹⁄₄" x 10" (8.3 x 25.4 cm)

through the wall

D. 27" (68.6 cm) - 30" (76.2 cm)

above gas cooking surface
24" (61.0 cm) - 30" (76.2 cm)
above electric cooking surface

E. Wall cap

20"

(50.8 cm)

9"

(22.9 cm)

1"

(2.5 cm)

4

¹⁄₁₆" (10.3 cm)

1

³⁄₄"

(4.4 cm)

4

³⁄₄"

(12.1 cm)

³⁄₄"

(2.0 cm)

29

¹⁵⁄₁₆" (76.0 cm)

1

¹⁄₂"

(3.8 cm)

Page 1 of 2

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system. 6" (15.2 cm) or Larger
Round Vent System

Vent Piece

Round

45° elbow

2.5 ft (0.8 m)

90° elbow

5.0 ft (1.5 m)

6" (15.2 cm) or larger
wall cap

0.0 ft (0.0 m)

3

¹⁄₄" x 10" (8.3 cm x

25.4 cm) to 6"
(15.2 cm) or larger

4.5 ft (1.4 m)

3

¹⁄₄" x 10" (8.3 cm x

25.4 cm) to 6"
(15.2 cm) or larger
90° elbow

5.0 ft (1.5 m)

PRODUCT DIMENSIONS

Example vent system

Maximum Recommended Length = 50 ft (15.2 m)

1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight

= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)

Length of 7" (17.8 cm) system

= 13.0 ft (3.9 m)

Wall cap

90˚ elbow

2 ft (0.6 m)

6 ft (1.8 m)