background image

EVERY 150 HOURS

1. Cables - Wearing gloves, wipe cables with an oil

soaked rag.

YEARLY

1. Hydraulic Tank - Drain hydraulic tank while oil is

warm.Clean

suction

strainer

and

filler

strainer with compressed air. Replace return line
filter. Refill tank with hydraulic oil. Filter oil to 10
microns before filling tank. See paragraph 4-3
for recommended hydraulic oils. Tank capacity is
35 gal. (132.5l.).

NOTE

The suction strainer and filler strainer are located
inside the hydraulic tank. They are accessible by

removing the tank lid secured by eight self-tapping
screws. A gasket is required for reassembly.

2. Spindle Assembly - Drain spindle housing. Refill

with EP80W-90 gear oil. Capacity is 26 fl. oz.

4-3 RECOMMENDED HYDRAULIC OILS

Recommended hydraulic oils are listed in Table 4-3
(page 13). Other brands may be used provided they
are equivalent. Approved hydraulic oils may be
mixed provided that anti-wear oils are mixed with
anti-wear oils. All hydraulic oils listed in Table 4-3
are anti-wear oils. Do not use motor oil or trans-
mission oil.

Figure 4-1 Lubrication

To Remove Yoke Shield:
Press all three tabs with
screwdriver and slide
cover back.

Before Each Use

20 Hours

Before Each Use

Replace Yearly
Check Before Each Use

40 Hours

40 Hours

40 Hours

150 Hours

12

Figure 4-2 Driveline Universal Joint

Advertising