Bush Hog SM 60 User Manual

Page 17

Advertising
background image

D. Turn motor 180º. Reinstall bolts retaining motor

to spindle housing.

E. Reinstall hydraulic fittings, and hoses. Replace

fitting O-rings as necessary.

4-10 TROUBLESHOOTING

Cleanliness is of primary importance for obtaining
satisfactory life of hydraulic components. The life of
hydraulic components is dependent upon the
degree of contamination in the hydraulic oil.
During usage, proper oil filling and servicing of fil-
ters, breather, tank, etc., cannot be over empha-
sized.

The hydraulic system must be cleaned after a major

Table 4-3 List of Recommended Hydraulic Oils

Manufacturer

Hydraulic Oil

Manufacturer

Hydraulic Oil

Chevron

AW46

Mobil

DTE-25

Gulf

Harmony 46AW

Union 76

Hyd. Oil AW215

Texaco

Rando HD46

Exxon

Magnas A15

Citgo

AW46

Exxon

Nutoh 46

Shell

Tellus 46 HY Oil 46

Standard

EP Hyd. Oil #1

14

contamination such as pump failure. This requires
removal and individual flushing and cleaning of all
components and lines that were exposed to the
contaminated oil flow. Flushing of the system
components should be done with a suitable sol-
vent or diesel fuel.
Clean the suction strainer,
replace the return line filter, and refill tank with new
hydraulic oil.

Troubleshooting procedures are listed in Table 4-4.
If the problem cannot be solved or replacement
parts are necessary, contact your authorized Bush
Hog dealer. Please have ready your machine
name, serial number, model number, purchase
date, and exact cause or description of problem.

Figure 4-4 Hydraulic Motor

Spindle Housing

Motor

Hydraulic Fittings

Return Line Hose

Pressure LIne

Advertising