Login Setup :
Header is.......................Enabled
Password is.....................Disabled
Menu is.........................Enabled
Auto Connect Port is............Module 3,Port 1
Auto Connect is.................Disabled

SERIAL PORT DS72 modules perform data rate conversions for devices using

CONFIGURATION

different serial configurations.See Appendix A, “SPECIFICATIONS” for
available serial parameters. Default Serial Port Configurations are
9600 bps, 8 data bits, 1 stop bit, no parity, Xon/Xoff disabled, RTS
high, and DTR low.
From the configuration menu, select #2, “Serial Port
Configuration”, followed by <cr>. The DS72 unit displays the following
table:

Module 1 Serial Port Configuration :

Port

Device
Name

Baud
Rate

Word
Size

Stop
Bits

Parity

Xon/
Xmit

Xoff/
Recv

Line
DTR

Drive
RTS

1

EIA-232

9600

8

1

None

Off

Off

High

High

Save.......1 Parity............5
Baud Rate..2 Xon/Xoff..........6
Word Size..3 RTS Line Driver...7
Stop bits..4 DTR Line Driver...8

Enter Request :

Select the corresponding number to configure baud rate, word size, stop
bits, parity...

NOTE: DTR is unchangeable when configuring the serial port.

For example, to change the baud rate to 115.2K, select #2, “Set Baud Rate,”
followed by <cr>.

The DS71 displays the following list of available baud rates:

1 for 300
2 for 600
3 for 1200
4 for 2400
5 for 4800
6 for 9600
7 for 19200
8 for 38400

9 for 57.6K

A for 76.8K
B for 115.2K

Enter Request :

Type "B" for 115.2K baud rate. The DS72 responds with the new
configuration status: