DS72 HOST MODULE OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

22

Allow approximately 10 seconds for the unit to reset.

ASCII To reset the DS-Series Unit using the ASCII character string method,
Character

send the following command:

String

$BTRESET<cr>

DIAGNOSTICS To detect hardware, cabling, or configuration problems upon initialization

of power, the DS72 executes a diagnostic sequence. To help determine
the cause of the problem, the DS72 has a CX LED located on the front
panel of the unit. Upon initialization of power, refer to the following table
for interpretation.

INDICATION

INTERPRETATION

Not lit

Normal unconnected operation

Brief flash followed by a solid illumination

Established connection on network port or serial port

Flashes 1 time per cycle

Hardware or NIC problem

Flashes 2 times per cycle

Configuration error

Flashes 3 times per cycle

Cable or hub connection fault

Flashes 4 times per cycle

Duplicate IP address

Remains lit without a brief flash prior to
illumination

Memory error

NOTE: Diagnostic indications override a connection indication.