English – Beyerdynamic MCS 20 User Manual

Page 45

Advertising
background image

MCS 20 – MCS 223 Microphone Unit

45

english

No.

Description

Value

range

Factory

setting

14

“FiFo” = “Requ” + “Free”:
0 = MCS 223 does not turn off another microphone unit
1 = MCS 223 turns off another microphone unit

0 or 1

1

15

“FiFo” = “Requ” + “Free”:
0 = MCS 223 is not turned off by another microphone unit
1 = MCS 223 is turned off by another microphone unit

0 or 1

1

16

Warning signal in the “Free” mode before the speech time has elapsed;
0 = no warning signal

0 ... 59 sec.

45

17

After the speech time has elapsed in the “Free” mode
0 = Timer indicates the exceeded speech time (counts up)
1 = MCS 221 is turned off

0 or 1

0

18

Warning signal in the “Request” mode before the speech time has elapsed;
0 = no warning signal

0 ... 59 sec.

45

19

After the speech time has elapsed in the “Request” mode:
0 = Timer indicates the exceeded speech time (counts up)
1 = Timer stops (activated MCS 221 is turned off and the registered MCS 221
must be activated by the chairman with the “Requ” button)
2 = Timer starts again (activated MCS 221 is turned off and registered
MCS 221 is turned on)

0 ... 2

2

20

Speech time is displayed in minutes (applies to “Free” and “Request” mode
(no. 20 and 21 are added)

0 ... 99 min.

2

21

Speech time is displayed in seconds (applies to “Free” and “Request” mode
(no. 20 and 21 are added)

0 ... 59 sec.

30